Maintenance and Lubrication Schedule
Resecure, replace or correct as needed
Use Braun 32840-QT (Exxon
®
Univis HVI 26)
K\GUDXOLFÁXLGdo not mix with Dextron III or other
K\GUDXOLFÁXLGV&KHFNÁXLGOHYHOZLWKplatform
lowered fully and roll stop unfolded fully. Fill
WRZLWKLQßRIWKHERWWRPRIWKHßÀOOWXEH
(neck).
Tighten, repair or replace if needed.
Tighten, repair or replace if needed.
Inspect cotter pins on platform pivot pin (2)
Hydraulic Fluid (Pump) - Check level. Note: Fluid
should be changed if there is visible contamination.
,QVSHFWWKHK\GUDXOLFV\VWHPF\OLQGHUKRVHVÀW-
WLQJVVHDOVHWFIRUOHDNVLIÁXLGOHYHOLVORZ
,QVSHFWF\OLQGHUVÀWWLQJVDQGK\GUDXOLFFRQQHFWLRQV
for wear, damage or leaks
Inspect outer barrier cylinder hose assembly (hose,
fasteners, connections, etc.) for wear, damage or
leakage (if equipped)
4500
Cycles
Perform all procedures listed in previous sections also
1500
Cycles
Resecure, replace or correct as needed.Remove pump module cover and inspect:
+\GUDXOLFKRVHVÀWWLQJVDQGFRQQHFWLRQVIRU
wear or leaks
• Harness cables, wires, terminals and connec-
tions for securement or damage
• Control board, circuit breaker, power switch and
lights for securement or damage