SYSTEMS DESCRIPTIONS
IN-Limit Microswitch
The IN-Limit microswitch is located in the inboard
mounting position of the platform carrier plate.
To adjust:
1. Power or manually move the ramp to the fully
stowed position.
2. Remove the ramp top plate (cover).
3. With the ramp in the stowed position loosen the
IN-Limit microswitch mounting screws.
4. Slide the switch body outward until resistance is
felt from the switch being fully depressed.
5. Tighten the mounting screws in this position.
6. Replace the ramp top plate (cover), before oper-
ating the ramp.
Figure N
Manual Release Signal Microswitch
The MR-Signal microswitch is located behind the
electric motor mounting plate.
To adjust:
1. Power or manually move the ramp to the fully
stowed position.
2. Remove the ramp top plate (cover).
3. Disengage the manual release T-handle to so
the ramp is in the manual release state.
4. Loosen the MR-Signal microswitch mounting
screws.
5. Slide the switch body toward the motor mount-
ing plate until resistance is felt from the switch
being fully depressed.
6. Tighten the mounting screws in this position.
7. Re-engage the manual release T-handle.
8 . Replace the ramps top plate (cover), before
operating the ramp.
Figure M
Ramp in Fully-Stowed Position
(As viewed from under the carrier plate)
IN-Limit
Microswitch
Ramp in Fully-Stowed Position
MR-Signal
Microswitch