the inner part can be cleaned by means of a
brush. The removable scale filter is dishwasher-
proof.
Descaling
In order to extend the lifetime of the kettle, it
should be descaled regularly.
Boil 0.8 l water in the kettle.
Important: Switch off the kettle and add 0.4 l
household vinegar (4% acid). Do not boil
the contents as it may cause spilling being a
danger of scalding.
Let the mix of water and vinegar sit in the
kettle overnight.
Empty the kettle and rinse the inside thor-
oughly with fresh water. Fill the kettle with
fresh water and boil it.
Empty the kettle and rinse it again with fresh
water.
If the kettle still contains scale, repeat this
procedure.
To remove any scale from the scale filter, you
may soak it in diluted vinegar.