Braun Personal Lift 403 Bedienungsanleitung Seite 4

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 3
Braun Corporation FMVSS No. 403 Quick Reference Installation Sheet 34274 Rev. A
K
MP916
0.010Ω
.5% R
321
321
321
LCD MODULE
8.00M
L_DN
B_UP
L_OUT
L_UP
B_DN
L_IN
50# CAL
O_BAR
D14
J27 U?
CYCLE
DIAG
U15
U11
U10
U2
J9
J11
J10
J17
J16
J14
J8
J5
J21J19
J20
D9
D6
D8
D7
D13
D11
83J93J
K7K10
D12
D10
100
VHA
C12
220
CFK
C18
100
VHA
C13
MAG_SW
HAND-1
HAND-2
INT
D/S
U/D
J29
J30
J22
J25
10 9 8 7 6
5
J4
SVC LIGHT
2
32J4
2J
2
3
3
3
1
4
2
45
R55
Y2
8.00M
Y2
R54
R57
R60
R61
R52
R42
Lift_Out Floor_SW
R41
R40
R39
R27
R77
R53
R68
C10
C5
C8
C4
C17
C14
C11
J37
JIHG
L
A
B
CD
4 3 2 1
RL11
RL11
220
35A
220
35A
B - UP
B - DN
L - OUT
L - IN
100419-001 REV
HI
LO
GND
PWR
LIGHTS
ALARM VALVE PUMP
R31
R30
C2
R21
R32
R34
R33
R35
R46
R58
R49
R51
R44
R36
R47
R45
R37
R70
R72
D5
D4
D3
D2
R26
R75
U5
R29
R76
J35
54J74J
J15
C23
C19
R64
R62
R78
R48
R69
D16 D17
C6
J13
SW_1 SW_0
J6
J36
J32
MAT
J40
U20
FL_CL
Bit_1
Bit_0
50# CAL
O_BAR
U11
K7K10
220
CFK
6C9
C18
C17
V104
RL
1
R32
1001
R34
1001
R33
1001
R35
1001
1001
R26
2400
R29
2051
J
4
FL_CL
Bit_1
Bit_0
The outer barrier will not raise if occupied.
A visual and audible warning will activate if the
threshold area is occupied when the platform is at
least one inch below floor level.
Platform movement is prohibited beyond the posi-
tion where the inner roll stop is fully deployed (up).
Lift platform movement shall be interrupted unless
the outer barrier is deployed (up).
Vehicle movement is prevented unless the lift door
is closed, ensuring the lift is stowed.
Lift operation shall be prevented unless the
vehicle is stopped and vehicle movement is
prevented.
The platform will not fold/stow if occupied.
The inner roll stop will not raise if occupied.
Verify platform lighting when lift is deployed and
pendant illumination when lift is powered.
4
Floor Level Switch
The Floor Level switch stops upward travel of the platform
during the Up function (activated by the torque tube-mounted
Floor Level cam). Position the lift platform 1" above floor
level using the manual operation system (detailed on
opposite side of this sheet). Loosen the clamp securing the
torque tube-mounted Floor Level cam. Rotate the cam until
the Floor Level switch is activated (cam depresses switch).
Note: Check the floor level position of the platform and the
inner roll stop after powering the pump. Hydraulic pressure
may affect platform height slightly. Fine tuning adjustment
(tweaking) of the Floor Level switch may be required.
The inner roll stop must rest properly on the vehicle floor
when the lift is deployed. Adjust the inner roll stop only if
necessary (refer to the service manual).
Calibration and Floor Level Adjustment
Floor Level Switch
Floor Level Cam
Torque Tube
Cam depressing switch.
5
FMVSS 403/404 Certification Checklist
The operations listed below must be functionally verified.
Platform Sense Calibration
1. There must be no weight on platform.
2. Press hand-held pendant UP switch to raise platform a minimum
3" above stow level.
3. Press and hold control board 50# CAL. button. While pressing
the 50# CAL. button, press and hold the hand-held pendant
STOW switch (button). The platform will lower to stow level
(begin stow function), and then start to raise. Release 50#
CAL. button immediately when platform starts to raise from stow
level.
4. After calibration, the LCD screen should read “PF OCCUPIED”
whenever there is 50 lbs. or more present on the platform. The
50 pound platform sensing is now calibrated.
Ground Sense Calibration
1. Press hand-held pendant DOWN switch to lower platform fully to
ground level.
2. While continuing to press the pendant DOWN switch, press and
then release the control board O_BAR GND. button.
3. Release the pendant DOWN switch.Ground level sensing is now
calibrated.
Outer Barrier Occupied Calibration
1. Press hand-held pendant DOWN switch to lower platform fully to
ground level.
2. Once outer barrier is fully unfolded (ramp position), release the
pendant DOWN switch.
3. Press and hold the control board O_BAR GND. button. While
holding O_BAR GND. button, press hand-held pendant UP
switch to raise the outer barrier. Be sure to release O_BAR
GND. button when outer barrier reaches approximately half full
up (vertical) position.
4. After calibration, the LCD screen should read “OUT-BAR OCCU-
PIED” whenever there is weight present on the outer barrier.
NUVL855RM24 Control Board
50# CAL
Button
O_BAR GROUND
LVL Button
34274 Rev. A
Dual
Outer Barrier
Threshold
Area
Platform
Lighting
Visual and Audible
Threshold Warning
Platform
Inner
Roll Stop
DOT — Public Use Lift
Public use vehicle manufacturers
are responsible for complying with
the lift lighting requirements in Fed-
eral Motor Vehicle Safety Standard
No. 404, Platform Lift Installation in
Motor Vehicles (49 CFR 571.404).
Seitenansicht 3
1 2 3 4 5 6 7 8

Kommentare zu diesen Handbüchern

Keine Kommentare