Braun Corporation FMVSS No. 403 Quick Reference Installation Sheet 32494
Maintenance and Lubrication
Specified (recommended) Available Braun
Lubricant Type Lubricant Amount Part No.
LO - Light Oil
LG - Light Grease
Light Grease Lubriplate 14 oz.
(Multipurpose) Can
Light Penetrating Oil LPS2, General Purpose 11 oz.
(30 weight or equivalent) Penetrating Oil Aerosol Can
Stainless Stick Door-Ease 1.68 oz.
Style (tube) Stick (tube)
DE - Door-Ease
15807
15806
15805
See the Maintenance/Lubrication Schedule for recommended applications per number of cycles.
Lubrication Diagram
DO
W
N
D
L
O
F
U
P
OF
N
U
LD
Platform
Outboard
Platform
Inboard
Parallel Arm
Pivot Pins (8)
LO
Lift-Tite Latch Dampening
Spring (2 springs - 4 Points)
LO
Parallel Arm
Pivot Pins (8)
LO
Inboard Locator
Pivot Points
LO
Platform Pivot Pin (2 Points)
LO
Platform Fold Axles (2)
LO
UHMW Bearing (4)
DE
Rotating Pivot
Slide Arm Pivot Pins
LO
Switch Arm Pivot Pins (2)
LO
Lift-Tite Latches
(Tower Pivot Points - 2)
LO
Platform Fold Link Roller/Pin (4)
LO
Outer Barrier Hinge Pivot Points
(2) and
Outboard Platform Pivot Pins (2)
LO
Outer Platform Pivot Pins (2)
LO
Outer Barrier Activation
Foot Pivot Point (2)
LO
Outer Barrier
Arm Slots (2)
LO
Maintenance and
lubrication procedures
must be performed as
specified by an autho-
rized service techni-
cian. Failure to do so
may result in serious
bodily injury and/or
property damage.
W
A
RNING
Maintenance and Lubrication Schedule
Proper maintenance is necessary to ensure safe,
troublefree operation. Inspecting the lift for any
wear, damage or other abnormal conditions should
be a part of a regular service program. Simple
inspections can detect potential problems.
The maintenance and lubrication procedures speci-
fied in this schedule must be performed by a Braun
authorized service representative at the scheduled
intervals according to the number of cycles.
Braun dual parallel arm lifts are equipped with hard-
ened pins and self-lubricating bushings to decrease
wear, provide smooth operation and extend the
service life of the lift.
When servicing the lift at the recommended inter-
vals, inspection and lubrication procedures specified
in the previous sections should be repeated. Clean
the components and the surrounding area before
applying lubricants. LPS2 General Purpose
Penetrating Oil is recommended where Light Oil is
called out. Use of improper lubricants can attract
dirt or other contaminants which could result in wear
or damage to the components. Platform compo-
nents exposed to contaminants when lowered to the
ground may require extra attention.
Lift components requiring grease are lubricated dur-
ing assembly procedures. When these components
are replaced, grease must be applied during instal-
lation procedures. Specified lubricants are available
from The Braun Corporation (part numbers provided
above).
All listed inspection, lubrication and maintenance
procedures should be repeated at “750 cycle”
intervals following the
scheduled “4500 Cycles”
maintenance. These
intervals are a general
guideline for scheduling
maintenance procedures
and will vary according
to lift use and conditions.
Lifts exposed to severe
conditions (weather, envi-
ronment, contamination,
heavy usage, etc.) may
require inspection and
maintenance procedures
to be performed more
often than specified.
Maintenance Indicator: The Lift Ready green LED
mounted on top of the pump cover will begin to blink
after every 750 cycles. The blinking LED will not affect
the functions of the lift, but is a reminder to complete
necessary maintenance and lubrication.
Once the lift has been serviced, fully stow the lift. Once
stowed, press the UP button on the hand pendant and
the Floor Level Set button on the back side of the pump
cover until the Lift Ready green LED stops blinking.
Discontinue lift use immediately if maintenance
and lubrication procedures are not properly performed,
or if there is any sign of wear, damage or improper
operation. Contact your sales representative or call
The Braun Corporation at 1-800-THE LIFT. One of our
national Product Support representatives will direct you
to an authorized service technician who will inspect
your lift.
Outer barrier hinge pivot points (2)
Outer barrier arm slots (2)
Outboard platform pivot pins (2)
Outer barrier activation foot pivot pins (2)
Platform fold link rollers and pins (4 sets)
Outer platform pivot pins (2)
Lift-Tite
latches (tower pivot points - 2)
Lift-Tite
latch gas (dampening) spring pivot
points (2 springs - 4 points)
Inspect Lift-Tite
latches and gas springs for wear
or damage (bent, deformed or misaligned), posi-
tive securement (external snap rings) and proper
operation
Apply Light Oil - See Lubrication Diagram
Apply Light Oil - See Lubrication Diagram
Apply Light Oil - See Lubrication Diagram
Apply Light Oil - See Lubrication Diagram
Apply Light Oil - See Lubrication Diagram
Apply Light Oil - See Lubrication Diagram
Apply Light Oil - See Lubrication Diagram
Apply Light Oil - See Lubrication Diagram
Resecure, replace defective parts or otherwise
correct as needed. Note: Apply Light Grease to
Lift-Tite
latch tower pivot point if replacing latch.
750
Cycles
Seitenansicht 6